Laicai MagnesiumGreen Magnesium New Materials
Fire-rated Duct Board
Class A1 (GB 8624-2012)

Fire-rated Duct Board

Fire Ducts · Verified Fire Resistance

Fire-rated duct boards are specialized magnesium inorganic fire boards used to build smoke-exhaust ducts and fire-resistant duct encasement. They meet building fire-code requirements for the fire resistance of smoke control systems — a critical material for tunnels, underground spaces and public-building fire engineering.

Specifications

ItemValue
Reaction to fireA1 non-combustible[GB 8624-2012]
Fire resistancePer duct-system fire resistance test report[GB 55037-2022][Class A1 Non-combustible Fire Test Report]
Applicable systemsSmoke-control ducts; fire encasement of ventilation ducts
ThicknessSelected per fire resistance; typically 9–20mm
System supportFlange, stud and installation details provided

Applications

Underground garages and utility tunnels smoke control
Tunnel fire ventilation
Hospital and commercial complex smoke-exhaust ducts
Fire encasement for industrial plant ventilation

Testing & Certifications

Class A1 Non-combustible Fire Test Report

Nationally accredited fire-building-materials testing body

Certificate number and scan will display once company credentials are uploaded; stamped copies available on contract.

Fire Protection Product Certification

Fire product conformity assessment body

Certificate number and scan will display once company credentials are uploaded; stamped copies available on contract.

FAQ

What is the fire resistance duration of the duct board?+

Fire resistance depends on board thickness, assembly and installation details, and must be verified by full duct-system fire tests. Provide your project's required fire resistance duration and we will supply the matching assembly details and test documentation.

Why must fire ducts use Class A1 boards?+

Smoke-control systems are life-saving egress paths during fires. GB 55037-2022 sets strict requirements for duct material reaction to fire. Class A1 materials contribute no fuel and no flame spread, preserving duct integrity in a fire.

Do you provide installation details?+

Yes — we provide detail drawings for duct fabrication, flange connections, stud fixing and penetration sealing, plus on-site technical support for first-section mock-up acceptance.

Can it be used in tunnel projects?+

Yes. Tunnel fire ventilation demands high fire resistance and moisture performance; magnesium duct boards are Class A1 and moisture-proof, used in underground spaces and tunnels. Technical consultation is available per project.

How is fire-rated duct board priced?+

Pricing is based on thickness, quantity and region. Submit a project inquiry with the required fire resistance and quantities — we provide both material pricing and system recommendations.

Related Products

Tell us about your project

Project inquiry, centralized procurement, dealership, export — response within 24 hours